BYLNR - M-100 STYRENE MONOMER,INHIBITED
- MSDS: BYLNR
- Manufacturer: SCIENTIFIC POLYMER PRODUCTS
- Product Name: M-100 STYRENE MONOMER,INHIBITED
- National Stock Number: 6810-00F045356
Product Identification
Product ID:M-100 STYRENE MONOMER,INHIBITED
MSDS Date:08/01/1994
FSC:6810
NIIN:00F045356
MSDS Number: BYLNR
Responsible Party
ONTARIO, NY 14519-5000
US
Emergency Phone: 716-265-0413
Info Phone: 716-265-0413
Cage: 0MWG0
Contractor
Telephone: 716-265-0413
Cage: 0MWG0
Ingredients
STYRENE MONOMER (SUSPECTED ANIMAL CARCINOGEN BY IARC -
CAS: 100-42-5
RTECS: WL3675000
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
Hazards
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:SKIN: MODERATE IRRITATION. INHALATION:
HARMFUL, MAY CAUSE MUCOUS MEMBRANE IRRITATION. EYES: IRRITATION
W/BURNS.
Explanation of Carcinogenicity:SEE INGREDIENTS.
Effects of Overexposure:DROWSINESS, NAUSEA, HEADACHE, FATIGUE,
DIZZINESS, IRRITATION, BURNS.
First Aid
First Aid:INHALATION: REMOVE TO FRESH AIR. GIVE MOUTH TO MOUTH IF
BREATHING STOPS. SKIN: WASH AREA W/SOAP & WATER. EYES: FLUSH
W/WATER FOR 15 MINS. OBTAIN MEDICAL ATTENTION IN ALL CASES.
Fire Fighting
Flash Point Method:TCC
Flash Point:86F
Lower Limits:1.1
Upper Limits:6.1
Extinguishing Media:DRY CHEMICAL, CO2, FOAM, WATER SPRAY
Fire Fighting Procedures:WEAR SCBA & PROTECTIVE CLOTHING. USE WATER
W/CAUTION. WATER MAY BE INEFFECTIVE IN FIGHTING FIRES DUE TO LOW
SOLUBILITY. USE WATER SPRAY/FOG FOR COOLING.
Unusual Fire/Explosion Hazard:FIRE/EXCESSIVE HEAT MAY VIOLENTLY RUPTURE
CONTAINER DUE TO BULK POLYMERIZATION, MAY FORM EXPLOSIVE PEROXIDES.
AUTOIGNITION TEMP: 914F. (SEE SUPP)
Accidental Release
Spill Release Procedures:RESTRICT WATER USE FOR CLEANUP. SOAK UP
W/INERT MATERIAL. USE VENTED DISPOSAL CONTAINERS. IF HARDENS,
CONTAIN/COLLECT AS ANY SOLID.
Handling
Handling and Storage Precautions:STORE IN A TIGHTLY CLOSED CONTAINER
AWAY FROM HEAT & SPARKS. CHECK PERIODICALLY TO CONFIRM INHIBITOR
CONTENT. IF BELOW, ADD EXTRA INHIBITOR, MIX WELL.
Other Precautions:AVOID CONDITIONS WHICH REMOVE OXYGEN FROM STORED
LIQUID. CONTAINERS THAT HAVE HELD STYRENE MONOMER, MUST BE CLEANED,
DRAINED & DRIED TO PREVENT FIRE HAZARD FROM RESIDUE. FOR LABORATORY
USE ONLY. NOT I NTENDED FOR DRUG, HOUSEHOLD/OTHER USES.
Exposure Controls
Respiratory Protection:IF NEEDED.
Ventilation:LOCAL EXHAUST
Protective Gloves:IMPERVIOUS
Eye Protection:SAFETY GLASSES
Other Protective Equipment:NONE
Work Hygienic Practices:REMOVE/LAUNDER CONTAMINATED CLOTHING BEFORE
REUSE.
Supplemental Safety and Health
RELEASE CAN CAUSE FIRE/EXPLOSION. MAY POLYMERIZE/RELEASE HEAT/GASES.
Chemical Properties
Boiling Pt:B.P. Text:293F
Vapor Pres:5
Spec Gravity:0.91
Solubility in Water:NEGLIGIBLE
Appearance and Odor:COLORLESS LIQUID
Percent Volatiles by Volume:100
Stability
Stability Indicator/Materials to Avoid:YES
OXIDIZERS, COPPER & COPPER ALLOYS, PEROXIDE, STRONG ACIDS, CATALYSTS.
Stability Condition to Avoid:HEAT, FLAME & SPARKS
Hazardous Decomposition Products:CO, CO2
Conditions to Avoid Polymerization:AVOID HEAT & LIGHT
Disposal
Waste Disposal Methods:DISPOSE OF IAW/FEDERAL, STATE & LOCAL
REGULATIONS.FLAMMABLE LIQUID UN 2055.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.